※. All kinds of verification and calibration, control and data transmission functions of the instrument are realized through wireless or USB data line between the instrument and notebook computer, without any operation on the instrument, which greatly improves the calibration accuracy and does not need to copy calibration data from the instrument through USB flash drive.
※ Data, figures and reports verified by various wireless control functions are automatically generated in the computer, which has more powerful functions of direct editing, management (flexible conversion of Word and Excel formats) and printing.
RS90001 instrument has nine functions:
1. Displacement verification and calibration: Check and calibrate the static linear characteristics of eddy current sensor; Sensitivity characteristics; Displacement system. Range of displacement range: 0~10mm.
2. Verification and calibration of shaft vibration: Verify and calibrate the dynamic amplitude-frequency characteristics of eddy current sensor; Shaft vibration system.
Dynamic calibration range: 0~250um; 0~400um.
3. Calibration and calibration of transmitter: Check and calibrate the linear characteristics and sensitivity characteristics of the shaft displacement / vibration transmitter; Dynamic amplitude-frequency characteristics.
Bently990, 991; MX2034 of METRIX company, WK-142K and WK-142T of SHINKAWA company, etc
-0.6~0.6mm; -25~25mil; -1~+1mm; 0.5~2.0mm; 0.5~2.5mm; 0.5~3.5mm; 0.5~4.5mm.
4. Calibration and calibration of expansion difference: Check and calibrate the static linearity and sensitivity characteristics of eddy current differential expansion sensor; Differential expansion system.
Check the calibration probe specifications: Bently φ 5 ~ φ 50 mm probe; EPRO φ 8 ~ φ 32 mm probe, etc..
5. Verification and calibration of absolute vibration: Check and calibrate magnetoelectric speed, piezoelectric speed and acceleration sensors; Vibration speed, amplitude and acceleration system. Such as Bently9200, 330500, 330400; epro9268; CTC102、136; Schenck VS-069 / 169, VS-068 / 168, etc.
6. Calibration and calibration of two-wire integrated vibration transmitter: Check and t-family:Arial; mso-fareast-font-family:宋体;mso-fareast-theme-font:minor-fareast;mso-hansi-font-family: Arial;mso-bidi-font-family:Arial'>、136; Schenck VS-069 / 169, VS-068 / 168, etc.
7, speed (overspeed) verification and calibration: Calibration of passive magnetoelectric, active magnetoelectric and eddy current speed sensors; Speed system. The acceleration / deceleration calibration can be performed. Forward / reverse calibration can be performed. Speed range: 1 ~ 10000 r / min (60 teeth);
8. Phase signal generating device with key: Achieve synchronization with the shaft vibration signal into the frame instrument calibration instrument system.
9. Signal source:
Check and calibrate the tile vibration, vibration speed, acceleration, shaft vibration, shaft displacement and rotation speed system;
Two independent zero-crossing sine wave signal outputs: The frequency and amplitude of the signal can be configured, with the maximum output signal frequency of 20KHz and the maximum output signal amplitude of 10000mv. Two independent negative bias voltage sine wave signal outputs: The bias voltage range is: 0 ~-22 VDC,